Top 100

KV-rate calculator

Calculations for liquids

We have compiled some calculation options for you. All calculations are purely practical formulas, i.e. simplifications for the respective case, which may only be used with the specified units.

kv Value
Formular Print

In order to calculate the kv value the flow Q, the density ρ1 of the media at the valve inlet and the pressure drop (Δp) across the valve must be known.

=m³/h
=kg/m³
=bar
Calculate
= m³/h
Flow
Formular Print

In order to calculate the flow Q the kvvalue, the density ρ1 of the media at the valve inlet and the pressure drop (Δp) across the valve must be known.

=m³/h
=kg/m³
=bar
Calculate
= m³/h
Pressure drop
Formular Print

In order to measure the pressure drop Δp the kv value, the density ρ1 of the media at the valve inlet and the flow Q must be known.

=m³/h
=kg/m³
=m³/h
Calculate
= bar

Calculations for gases

With the calculations for gases, one additionally distinguishes between the under-critical (p2 > p1/2) and over-critical cases (p2 < p1/2).

kv Value
Formular Print

In order to calculate the kv value the volumetric flow QN at 1013 hPa and 0°C, the standard density ρN of the media, the pressure drop (Δp) across the valve, the media pressure p2 downstream of the valve and the media temperature at the valve inlet must be known.

=Nm³/h
=kg/m³
=bar
=bar
=
Calculate
= m³/h
Flow
Formular Print

In order to calculate the flow QN the kv value, the standard density ρN of the media, the pressure drop (Δp) across the valve, the media pressure p2 downstream of the valve and the media temperature at the valve inlet must be known.

=m³/h
=kg/m³
=bar
=bar
=
Calculate
= Nm³/h
Pressure drop
Formular Print

In order to calculate the pressure drop Δp the kv value, the volumetric flow QN at 1013 hPa and 0°C, the standard density ρN of the media, the media pressure p2 downstream of the valve and the media temperature at the valve inlet must be known.

=m³/h
= Nm³/h
=kg/Nm³
=bar
=
Calculate
= bar