Part 2 FRITZ. In deep cold environment (03/23)

Objective: The functionality of the Buschjost valve with integrated end position detection is to be tested in a cold environment

Read full article as pdf file
Hall_Fritz_workspace_cryo_20230214_132532.jpg
Hall_Fritz_workspace_cryo_Ansteuerung.jpg
Hall_Fritz_workspace_cryo_minus41.jpg
Hall_Fritz_workspace_cryo_minus124.jpg
Hall_Fritz_workspace_cryo_minus133.jpg
Hall_Fritz_workspace_cryo_table.jpg

Conclusion:

  • As expected, the pure switching mechanism of the valve caused no problems under deep cold conditions. However, the Hall electronics could no longer reliably detect the switching cycles under these conditions.
  • The valve 2/904-40...46-1004-1012-F 24VDC is suitable for use in deep cold environments, however the Hall sensor « FRITZ » is not suitable to reliably display end positions under deep cold environmental conditions. A continuous environmental temperature of -60°C for the Hall sensor can, however, be readily recommended.
  • It should always be noted:

    The Hall sensor responds only to the proximity of the magnet on the magnetic head and thus detects only the "OPEN" position of the valve. Whether the valve is actually closed cannot be detected via the Hall sensor!