Product data sheet
Valve
1-041-03-0004-5358-9E-NO,
May 11, 2025
Seat Valve electrically force-controlled
Series 1/041-FL
Valve 1/041-03/0004/5358-9E-NO AC
The solenoid valve type 1/041-FL with flange connection, in the forced control type. The sealing element is a metal piston with annular seat seal made of PTFE. The valve type is robust and suitable for high pressures up to 70 or 100 bar. 1/041-FL in flanged version according to DIN EN or according to ANSI standard made of steel/stainless steel. In valves with override control, the servo principle is coupled with direct actuation. Forced control valves combine the advantages of these aforementioned control types. The valves switch from 0 bar up to the maximum operating pressure and are to be used where direct-acting valves are applied.
For more information follow this link:
Valve 1/041-03/0004/5358-9E-NO AC
Datasheet explicit
Version | 1/041- | |
Type of valve | Seat Valve electrically force-controlled | |
Connection type, valve seat | 03 | DN25 25mm |
Kv-value (Δp = 1 bar H₂O) | ||
Housing | 00 | P250GH+N - C22.8 PN160 |
Sealing | 04 | PTFE |
Voltage type | 5 | AC |
Solenoid power | 35 | 75W |
Protection class | 8 | Ex protection |
Valve option | 9E-NO | normally open + Magnetic switch 2-fold OPEN and CLOSE induc. NAMUR |
Pressure rating | PN100 | |
System pressure | 0 - 70 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC | |
Temperature Medium | from -10 °C to 40 °C | |
Temperature Environment | from -10 °C to 40 °C | |
Mounting position | Pipeline horizontal, Actuator vertical up | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 Solenoid .358 Steel K05935XX | terminal box M16x1,5 | 100%ED | Cable clamping range 6.5 - 9.5mm | Duty cycle 100% | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Gas: Ex II 2G Ex e mb IIC T4 Gb | Staub:Ex II 2D Ex mb tb IIIC T130°C Db | |
Valve option | 9E-NO | normally open + Magnetic switch 2-fold OPEN and CLOSE induc. NAMUR |
Description | Valve closes with continous voltage | Magnetic field sensor | Turck BIM-PST-Y1X Ex Zone 1, intrinsically safe | place of install.: top | Valve position: OPEN and CLOSE | Order isolating switch amplifier separately | |
Leakage rate | B - EN 12266 [Test medium air or nitrogen, 20°C room temperature] | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Customs export | Customs tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N |