Valves for H2 storage technology for fuel cell vehicle refueling.

2/2-way seat valve with pneumatic NC actuator. The field of application for valve type 2/975 is the hydrogen filling station, developed as a refuelling/safety shut-off valve for high pressures > 500 bar. Marking for the explosion-proof version: Ex II 2G Ex h IIC T4...T3 Gb X.

Valves of the control type 'servo-assistant' require a pressure difference of at least 1 bar between valve inlet and outlet for perfect functioning.

Link to this product

This series includes:

Technical informations

ConnectionsG3/4, G1, G1/2
PressureMin: 1 bar, Max: 600 bar
TemperatureMin: -40 °C, Max: 80 °C
MediaHydrogen H2
Housing materialsAISI S165M - 1.4418
SealingPeek/PCTFE