Product data sheet
Valve
3-050-27-1004-T242-HA-1U,
June 14, 2025
Seat Valve electrically force-controlled
Series 3/050
Valve 3/050-27/1004/.242-HA-1U AC, DC

The valve is closed in the rest position - (NC). The valve operates from 0 bar, a minimum pressure difference is not required. These valves are used where the safe valve function is desired independent of the flow rate. Feature: 1 limit switch for position CLOSED, different temperatures, manual operation via handwheel, partial railway approval BN 411 002 , DIN EN 50155

For more information follow this link:
Valve 3/050-27/1004/.242-HA-1U AC, DC
Link Icon
Datasheet explicit
Version3/050-
Type of valveSeat Valve electrically force-controlled
Connection type, valve seat27G6/4 40mm
Kv-value (Δp = 1 bar H₂O)26 m³/h
Housing10CW617N brass
Sealing04PTFE
Voltage type--To be specified later
Solenoid power2426W
Protection class2IP65
Valve optionHA-1Unormally closed + Manual operation HA + Reed contact 2-wire RC27-S
Pressure ratingPN40
System pressure0 - 4 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -40 °C to 180 °C
Temperature Environmentfrom -40 °C to 40 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1x Temp.-Solenoid T242 Steel | with plug connection, voltage tolerance -30%/+25% 1 Connector B0040.00048 | UL94-HB | 4x90° EN 175301-803 Form A | IP65 |
Valve optionHA-1Unormally closed + Manual operation HA + Reed contact 2-wire RC27-S
DescriptionValve opens with continuous voltage | Hand wheel under the valve body | Reed contact | | Contact type: normally open contact | place of install.: top / horizontal | Signal: closed | M12 socket, 4-pin, angled, max. 0.75 mm² | B0040.000224
Leakage rateA - EN 12266-1 [Test medium air or nitrogen, 20°C room temperature]
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N