Product data sheet
Valve
B3527-0804-5248-9E,
May 10, 2025
Seat Valve electrically force-controlled
Series 35-08
Valve B3527/0804/5248-9E AC

2/2-way solenoid valve for gases and solid-free liquids. The sealing element is a flat metal piston with a ring-shaped seat seal. The piston is guided in the valve cover by a PTFE piston ring. The valve type is robust and suitable for a wide range of applications due to the use of PTFE material.

For more information follow this link:
Valve B3527/0804/5248-9E AC
Link Icon
Datasheet explicit
VersionB
Type of valve35Seat Valve electrically force-controlled
Connection type, valve seat27G6/4 40mm
Kv-value (Δp = 1 bar H₂O)24 m³/h
Housing08AISI 316 Ti - 1.4571(81)
Sealing04PTFE
Voltage type5AC
Solenoid power2430W
Protection class8Ex protection
Valve option9Enormally closed + Magnetic switch 2-fold OPEN and CLOSE induc. NAMUR
Pressure ratingPN40
System pressure0 - 16 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC
Temperature Mediumfrom -40 °C to 60 °C
Temperature Environmentfrom -40 °C to 60 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Solenoid .248 Steel K05924XX | terminal box M16x1,5 | 100%ED | Cable clamping range 6.5 - 9.5mm | Duty cycle 100% | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Gas: Ex II 2G Ex e mb IIC T4 Gb | Staub:Ex II 2D Ex mb tb IIIC T130°C Db |
Valve option9Enormally closed + Magnetic switch 2-fold OPEN and CLOSE induc. NAMUR
DescriptionValve opens with continuous voltage | Magnetic field sensor | Turck BIM-PST-Y1X Ex Zone 1, intrinsically safe | place of install.: top | Valve position: OPEN and CLOSE | Order isolating switch amplifier separately
Leakage rateB - EN 12266 [Test medium air or nitrogen, 20°C room temperature]
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N