Product data sheet
Valve
A7540-0615-5248-NO,
September 15, 2026
Seat Valve electr. direct
Series 75-0615
Valve A7540/0615/5248-NO AC

Compact 3/2-way solenoid valve / switching valve (changeover valve). The valve is particularly suitable for the controlled distribution and switching of gaseous or liquid media. One inlet can be switched selectively to one of two outlets. Due to its changeover valve design, the flow path remains open to at least one outlet during the switching process at all times, preventing any unintended interruption or shut-off of the media flow.

For more information follow this link:
Valve A7540/0615/5248-NO AC
Link Icon
Datasheet explicit
VersionA
Type of valve75Seat Valve electr. direct
Connection type, valve seat40G1/4 1mm
Kv-value (Δp = 1 bar H₂O)0.026 m³/h
Housing06AISI 304 - 1.4301
Sealing15PEEK/PCTFE-HP
Voltage type5AC
Solenoid power2430W
Protection class8Ex II 2G Ex e mb IIC T4 Gb (Zone 1)
Valve optionNOnormally open
Pressure ratingPN300
System pressure0 - 200 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC
Temperature Mediumfrom -40 °C to 60 °C
Temperature Environmentfrom -30 °C to 55 °C
Mounting positionActuator upright (preferred) or horizontal
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Solenoid .248 Steel K05924XX | terminal box M16x1,5 | 100%ED | cable clamping range 6,5 - 9,5mm | Duty cycle 100% | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Gas: Ex II 2G Ex e mb IIC T4 Gb | Dust: Ex II 2D Ex mb tb IIIC T130°C Db
Valve optionNOnormally open
DescriptionNormally Open (NO): Open when de-energized, closes when electrically actuated.
Leakage rateA - EN 12266-1 [Test medium air or nitrogen, 20°C room temperature]
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N
Not applicable