Product data sheet
Valve
A9125-0804-5328-EB,
June 2, 2025
Seat Valve electrically force-controlled
Series A91-0804 Cryo
Valve A9125/0804/5328-EB AC

2/2-Way Solenoid Valve Made of Stainless Steel – Long-Spindle Design for Liquefied Gases This solenoid valve is specifically designed for use with liquefied gases such as LN2 (nitrogen), LCO2 (carbon dioxide), and—when selecting option F—also for liquid oxygen (LOX). The long-spindle design allows optimal insulation of the valve body. Since the solenoid actuator is positioned at a sufficient distance from the cold source, heat input remains negligible. Additionally, this valve design is compatible with EEx solenoids, making it suitable for use in Ex-Zone I. Our cryogenic valves are specially developed for applications requiring media temperatures as low as -196 °C.

For more information follow this link:
Valve A9125/0804/5328-EB AC
Link Icon
Datasheet explicit
VersionA
Type of valve91Seat Valve electrically force-controlled
Connection type, valve seat25G1 25mm
Kv-value (Δp = 1 bar H₂O)12 m³/h
Housing08AISI 316 Ti - 1.4571(81)
Sealing04PTFE
Voltage type5AC
Solenoid power3223W
Protection class8Ex protection
Valve optionEBnormally closed + Reed contact 2-wire RC12
Pressure ratingPN40
System pressure0 - 16 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC
Temperature Mediumfrom -196 °C to 60 °C
Temperature Environmentfrom -40 °C to 60 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Solenoid .328 Steel K05932XX | terminal box M16x1,5 | 100%ED | 1x solenoid 40W, 100%ED Cable clamping range 6.5 - 9.5mm | Duty cycle 100% | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Gas: Ex II 2G Ex e mb IIC T4 Gb | Staub:Ex II 2D Ex mb tb IIIC T130°C Db |
Valve optionEBnormally closed + Reed contact 2-wire RC12
DescriptionValve opens with continuous voltage | Reed contact | RC12-S 3m cable Art. B0044.000424 | Contact type: normally open contact | ATEX II 2G Ex mb IIC T6 Gb - 2D Ex mb IIIC T80°C Db IP67 | place of install.: top | Valve position: OPEN
Leakage rateB - EN 12266 [Test medium air or nitrogen, 20°C room temperature]
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N